¶ AFC is not supported
OpenAMS runs on its own host software, the one installed in
~/openams. Supporting the boards, their firmware and the host software is already a lot; we can't also support code someone else wrote to drive them. That includes AFC (Armored Turtle's Automated Filament Control), which drives OpenAMS boards with its own driver, built from a fork ofklipper_openams. On AFC, a stuck spool can be rewound at full power with nothing on the host to stop it, and it has burned out AMS feeder motors (what happens). Mainboard firmware 2.0.26.3 adds safeguards on the board. Use OpenAMS (moving from klipper_openams).
¶ No spring other than the one supplied is supported
Not a stiffer one, not a different one. Use the buffer spring that came with your hardware: the one in the FPS kit on OpenAMS 1, or the stronger spring that comes with the Cortex Bridge on 0AMS. A stronger spring never fixes a buffer that triggers early. It overpowers the AMS's grip and your extruder's, and the filament slips, grinds and gets stuck in the toolhead. Fix the friction instead (section 3).
¶ Only use 3 mm tubing
3 mm inner diameter, 4 mm outer, from the buffer all the way to your extruder. Not 2 mm, and not Bambu Lab's 2.5 mm. A narrower tube adds enough friction on the long run to the toolhead that the buffer compresses before the filament reaches your extruder, and the load stops short. If your extruder only takes 2 mm tube, put the printed 3-to-2 mm coupler just before it (the tube).
¶ Toolhead filament switch sensors are not recommended
Above all, never one in front of the extruder gears. The AMS knows the filament has arrived when it presses against your gears and pushes the buffer slide home. A switch in front of the gears takes force to trigger, and the buffer reads that force as arrival, so loads stop short. Even after the gears, a stiff switch may make the extruder skip. Never use an optical sensor: dust makes it read "filament" all the time (why).
¶ Keep the AMS stock, and use Bambu Lab reusable spools
No Hydra or other printed tray, no larger front rollers, no printed rims on cardboard spools. The AMS, its front and rear rollers and Bambu Lab's reusable spools were designed together and work as one system. Wind other filament onto Bambu Lab reusable spools with a respooler. Why: The AMS is one system.
This guide is built from the problems people actually brought to the OpenAMS Discord support channels: how to tell them apart, and the fixes that worked.
It covers both ways of running a Bambu Lab AMS on Klipper with OpenAMS:
| OpenAMS 1 | 0AMS (Cortex Bridge) | |
|---|---|---|
| What you add | A replacement mainboard inside the AMS, and the FPS board for the buffer | A Cortex Bridge board, connected to the Klipper computer by USB |
| The AMS | Its mainboard is replaced | Unchanged: it keeps its Bambu Lab board and firmware, and nothing is opened or flashed |
| The buffer | The OpenAMS FPS (filament pressure sensor), with the spring from the kit | Bambu Lab's own filament buffer, with the stronger spring that comes with the bridge |
| Connection | CAN bus | USB |
| Set it up with | The install and configure guides | Before you start and the 0AMS quick start |
Sections 1 to 5 and 7 apply to both. In section 6, each area says which one it is for.
It is written for the current OpenAMS (OpenAMSOrg/openams, installed in ~/openams with ./install.sh). If you still run the older klipper_openams plugin, move first; see Moving from klipper_openams. Older answers in the channels often refer to it; where they differ from this guide, follow this guide.
The OpenAMS guide covers installing and configuring. Its troubleshooting page matches each exact error message to a fix. This guide covers what those pages can't: how a multi-material printer works, what your printer has to do for it, and what went wrong for other people.
Contents
What you bought. OpenAMS lets a Bambu Lab AMS take orders from Klipper instead of from a Bambu printer, in one of two ways:
The Klipper plugin is free.
What the AMS does. The AMS does three things, and only these:
It is, in the maintainer's words, "a very simple device conceptually: [it] feeds until the filament bottoms out, and assumes it is in the toolhead. It is up to you to get your setup to take it in."
What your printer does. Everything else in a color change belongs to your printer:
On a Bambu printer, Bambu designed all of these to work together. On your Klipper printer, you built them, and you chose each one.
Why that matters. When each of those pieces works on its own, the whole system works. When one doesn't, no AMS setting can make up for it:
The AMS can only push and pull. Trying to make it push harder, or later, or at the same time as the extruder, turns a printer problem into ground-up filament and a jammed AMS.
The AMS protects itself, and that's a message. The AMS counts the filament as it moves. If its motor runs but the count stops, the filament is stuck somewhere. OpenAMS then stops the motor and pauses with loading speed too low or unloading speed too low; on OpenAMS 1 the bay LED also turns red. Without that stop, the motor would grind a flat spot into the filament, and the plastic dust would end up in the AMS's gears. When it stops, the most useful question is "where did the filament get stuck?", not "why did the AMS stop?" The maintainer, on the buffer slide triggering early:
"Don't think of the FPS slide as the problem. Think of it as the messenger. It's showing you where your filament path needs attention."
The same is true of every multi-material system: ERCF, BoxTurtle, Bambu's own. A rough filament path, a weak extruder or a half-working cutter makes any of them unreliable.
The support channels are run by the person who designs the boards, with help from experienced users. They are glad to help with anything OpenAMS:
That includes replacing a board that turns out to be faulty.
What they can't do is fix your printer from a distance. Most problems brought to support turned out not to be in OpenAMS at all, but in one of three places:
OpenAMS bugs and faulty boards do happen, and support will fix or replace them. They're just a small share of what goes wrong. Every hour spent tuning AMS settings around a printer problem is an hour that problem stays.
If this is your first multi-material printer, you're in good company: many people in the channels were. Read sections 2 and 3 before anything else. Learning how a toolchange works from the docs takes an evening. Learning it one support question at a time took one user five weeks (section 4).
OpenAMS is three things built together: the boards, their firmware and the host software that drives them. Each is written and tested against the other two, and support covers all three. Software someone else wrote to drive the boards is something support can't fix, test or answer for, so it isn't supported. AFC is the one people ask about: it drives OpenAMS boards with its own driver, built from a fork of klipper_openams. Questions about AFC belong with its authors.
Several OpenAMS 1 owners running AFC burned out first-stage feeder motors, each time after a tangled spool. Following AFC's driver (AFC-Klipper-Add-On, commit 5ea84ea):
auto_unload_on_failed_load (on by default), AFC then rewinds that same spool. During a print, stuck_spool_auto_recovery: True from AFC's AMS template does the same through TOOL_UNLOAD.Setups that still use the older separate fork of klipper_openams behave the same way, with more retries.
In Klipper the host owns every motion decision, and the MCU carries them out. An OpenAMS board is a little different: once the host starts a load or unload, the board runs that routine itself and ends it at the hub sensor or a time limit. That doesn't move the decision. The host chooses to rewind a spool it has just found stuck, so the host has to watch that rewind, and it has a way to stop it: setting the bay's error stops the board.
klipper_openams and OpenAMS don't have this problem: on a stall they set the bay's error, stop and pause for you, and never rewind a stuck spool by themselves.
To protect the motors from host logic that gets this wrong, mainboard firmware 2.0.26.3 adds safeguards on the board:
They are a backstop for the host, not a replacement for host logic. Update every OpenAMS 1 board to it (mainboard firmware).
On a board that isn't updated yet, on any host: if a rewind keeps running while the spool doesn't turn, switch the AMS off. Clearing errors doesn't stop a rewind that is already running.
| Word | What it means |
|---|---|
| Unit | One AMS. In the config it is [oams oams1], [oams oams2], and so on. |
| Bay | One spool position in a unit, numbered from 0. An AMS has four. oams1-2 is the third bay of the first unit. |
| Feeder (first stage) | The small motor at each bay. It pulls filament off the spool and into the hub. |
| Hub motor | The AMS's main motor. It pushes the selected filament down the tube to the toolhead, and pulls it back. |
| FPS / buffer | A spring-loaded slide between the AMS and the toolhead: the OpenAMS FPS on OpenAMS 1, or Bambu Lab's own buffer with a Cortex Bridge. Its reading goes from 0.0 (slide relaxed, no pressure) to 1.0 (slide pushed all the way, filament pressing hard against the extruder). It is how the AMS knows the filament has arrived: the buffer is the AMS's endstop. |
| Follower | After a load, the AMS keeps feeding gently, so that the buffer stays at a steady pressure while the extruder pulls filament in. |
| Filament group | A named set of one or more bays that serve one tool, for example [filament_group T0] with group: oams1-0. Two spools of one color in a group let a runout switch to the spare. |
Tool, T0, T1… |
What the slicer calls "filament 1", "filament 2". In the G-code it writes T1 where the color changes. Klipper then runs the T1 macro, which loads group T1. |
| Toolchange | Everything that happens between "printing color A" and "printing color B". |
ptfe_length |
The length of the path from the AMS to the extruder. On OpenAMS 1 the AMS feeds fast until it is 100 mm short of it, then slows down and watches the buffer. On a Cortex Bridge it feeds at full speed until the buffer starts to compress, and stops a load that runs about 200 mm past it. It is calibrated with OAMS_CALIBRATE_PTFE_LENGTH OAMS=<n> SPOOL=<bay> on OpenAMS 1 and on a Cortex Bridge with firmware 8 or later; with older bridge firmware you measure the path and convert it with cortex-bridge.py ptfe <mm>. |
| Cutter | A blade on the toolhead that cuts the filament above the melt zone. The extruder can then pull the old filament out. OpenAMS requires one. |
| Purge | The old color left in the nozzle has to be pushed out before the new color prints: a purge tower, a purge into a bucket, or a wipe. |
Most other multi-material systems, such as ERCF and BoxTurtle, drive the filament with stepper motors. A stepper moves a set number of steps, so as long as it doesn't skip, you know roughly where the filament is. When the filament slips, though, the count is wrong and nothing notices. That's why those systems grew sensors one at a time:
Many of those setups are a printer and an MMU designed separately and matched afterwards, improved one fix at a time.
The AMS works differently. Its motors are brushless (BLDC), which also makes them faster than steppers. They run a closed loop on motor current, with no step count, so the motor itself can't tell when the filament slips, especially at low speed. The AMS doesn't feed a set distance. It feeds until:
ptfe_length. When the motor runs but the count stops, OpenAMS stops with loading speed too low.Two things follow from that:
When the slicer's G-code says T1, the T1 macro calls _TX GROUP=T1, which runs these steps in order:
| # | Step | Who does it | What has to be true |
|---|---|---|---|
| 1 | Check and heat | Klipper | The hotend is hot enough to extrude. |
| 2 | Home, if needed | Your printer | |
| 3 | Cut | Your cutter: the cut coordinates in _oams_macro_variables, or your own OAMS_CUT macro |
The blade cuts all the way through. A nicked or half-cut filament stays connected, and nothing after this step can work. |
| 4 | Retract out of the extruder | Your extruder: extrusion_unload_length, then extrusion_unload_additional_length (250 mm by default) |
The cut end leaves the extruder gears completely. |
| 5 | Rewind | The AMS | The filament is free. If anything still holds it, the AMS stops to protect itself. |
| 6 | Load the new bay | The AMS, fast to ptfe_length − 100 mm, then slow until the FPS slide is pushed fully home (Cortex Bridge: full speed until the buffer starts to compress, then slow until it reads arrival) |
The path is smooth all the way to the gears, so that the slide compresses at the extruder, not halfway there on a snag. |
| 7 | Clean the nozzle | Your CLEAN_NOZZLE macro |
Your macro clears its own Z. |
| 8 | Reload | Your extruder: extrusion_reload_length |
The extruder grips the new filament and pulls it into the melt zone. |
| 9 | Purge and resume | Your slicer's purge tower or your macros |
Steps 3, 4, 6 and 8 are where most toolchanges fail, and in three of them the AMS is only waiting on your printer. If a step fails, OpenAMS pauses the print and turns the follower off, so the print doesn't carry on without filament, and RESUME finishes the toolchange from where it stopped (what to do then).
The print is paused, not lost. It waits for you to clear the problem, and then it carries on:
pause_idle_timeout in [oams_manager]), so the heaters and motors stay on and the printer keeps its position; it goes back to your own value when the print resumes or is cancelled. If the motors do go off, RESUME refuses with the printer lost its position: it never homes with a part on the bed, so the print has to be cancelled.OpenAMS: the toolchange to T1 failed at the <step> step: <reason> names the step that failed (home, heat, cut, retract or feed; the reload is part of the feed) and why. Quick triage maps each one to its usual cause.RESUME. It clears the AMS's faults itself, works out where the lane is, and runs only what is left: the toolhead part when the AMS had already fed the filament, the feed when nothing is loaded, the whole swap when the old filament is still loaded. Then the print carries on. If that fails too, the print stays paused with the new reason. RESUME also refuses while the toolhead doesn't hold the group the print was using (the print needs <group> loaded): load it and press RESUME again. An Unload or a Load you run while the print waits doesn't cancel the failed toolchange; RESUME still finishes it. If your RESUME macro stops before it retries (Mainsail's does when a runout_sensor sees no filament), run OAMSM_RETRY, then RESUME. How the macros run draws it.If the same step fails again, a retry won't help. Cancel the print and work through section 3 before the next one. A retry fixes one-off problems, like a tangle on the spool, not a cutter that doesn't cut or an extruder that doesn't grip.
A whole T0 → T1 toolchange on a Stealthburner with a Clockwork 2, a FilamATrix cutter and a Dragon hotend, drawn as a section through the real CAD. Each setting is measured as it moves (2:46, no sound).
To try your own values, or another hotend or extruder, use the toolchange simulator: pick your toolhead and watch the same toolchange run with your numbers.
The distances come from the FilamATrix CAD: 24.4 mm from the gear nip to the blade, and 61.9 mm from the blade to the Dragon's nozzle tip. On that toolhead the starting values are:
retract_length 20extrusion_reload_length 24.5extrusion_unload_length 30hotend_meltzone_compensation 0. Raise it a little if the nozzle drips while it waits and there's no silicone plug to park on: the reload then refills what dripped out.Tune them on your printer. The unload has to clear the gears. For the reload:
extrusion_reload_length to the distance from your gear nip to the blade.T1, and watch the nozzle during the reload.Too long, and the nozzle blobs on the tower. Too short, and the first lines after a change under-extrude.
The slicer only has to write T0, T1, … at the right moments, and purge after each one. OrcaSlicer and PrusaSlicer were made for the Prusa MMU, which shapes the filament's tip: out of the box they ram, cool, park and reload the filament around every T, and that fights the OpenAMS toolchange.
The slicer setup page does this for you. It makes OpenAMS copies of your Orca or PrusaSlicer profiles, has ready-made Orca profiles for the Vorons, and checks a sliced file. By hand, in OrcaSlicer:
T[next_extruder]. Put nothing else there; OpenAMS's macros do the work. Don't paste the toolchange macros into the slicer.T is written at the part and nothing purges.PrusaSlicer has no switch for ramming, so more has to change there: one extruder per filament, the cooling tube, parking and extra loading values at 0, the wipe tower on and "Prime all printing extruders" off in the print settings, and cooling moves 0 in each filament. The slicer setup page lists every setting and makes the copies from your export.
T0, filament 2 is T1, and so on.T1. You should see the T command and the purge, and no slicer retracts, cooling moves or ramming around it.PRINT_START … TOOL=[initial_tool], and have the start macro run T{TOOL} before the purge line. If the start macro loads a different tool than the first color in the print, the printer loads one color, primes, and immediately changes to another. The OpenAMS profiles add TOOL=[initial_tool] to the PRINT_START line for you.A group with two spools switches by itself when one runs out. The host compares the extruder's progress with the calibrated ptfe_length, picks a ready spare in the same group, and loads it. If it can't, it pauses with a reason, most often ptfe_length is not calibrated (0):
OAMS_CALIBRATE_PTFE_LENGTH OAMS=1 SPOOL=<bay> once per bay. On a Cortex Bridge the AMS feeds the filament to the extruder gears, measures the path there and rewinds it; stay with the printer.python3 ~/openams/tools/cortex-bridge.py ptfe <mm>, then set ptfe_length in the AMS's [oams] section.You don't have to remove or disable anything. OpenAMS only acts on a T command. With no bay loaded, load a spool by hand through a bypass tube and start a single-color print as usual. A single-color print sends no T command, so nothing happens in the AMS, and nothing goes wrong.
Each step builds on the one before it. Don't skip ahead.
The hardware is found, and Klipper starts.
python3 ~/openams/tools/cortex-bridge.py status shows every AMS online.Then python3 ~/openams/tools/agent/bringup_check.py --selftest ends with fail=0.
The buffer reads near 0.0 with the slide relaxed, and high when you push it home by hand: near 1.0 on OpenAMS 1, and often only about 0.75 for a Bambu buffer read through a Cortex Bridge. On OpenAMS 1, if it reads backwards, see 6.3.
The filament path passes the hand test in section 3.
Your extruder grips, and your cutter cuts, without the AMS involved (see the same section).
ptfe_length for each bay: OAMS_CALIBRATE_PTFE_LENGTH (OpenAMS 1, Cortex Bridge firmware 8 or later), or measured by hand on older bridge firmware (Runout above).
One load and one unload, watched: OAMSM_LOAD_TO_TOOLHEAD GROUP=T0, then OAMSM_UNLOAD_FROM_TOOLHEAD.
T1 then T0, watched. Then OAMS_TOOLCHANGE_TORTURE_TEST LOOPS=5.
A two-color test print, before trusting a long one.
These are the printer-side problems that came up again and again, each with the test that finds it. None of them is an AMS fault, and none of them can be fixed by an AMS setting.
Use 3 mm ID / 4 mm OD PTFE for the whole path, from the FPS slide to the extruder, ideally as one tube. That's what the system is designed for. Bambu Lab's own tubing is 2.5 mm ID, and 2 mm ID is common on printers. Both add enough friction on a long reverse-Bowden run that the FPS slide compresses before the filament reaches the gears, and the load stops short. "Most likely your PTFE tube is not all the way in, or has lots of bends, or you are not using 3 mm inner diameter PTFE" was the answer to a whole class of "AMS won't load" reports.
Watch for steps inside fittings. Many PC4-M6 push fittings are made for 2 mm ID tube. With a 3 mm ID tube in them, they leave a 1 mm internal step, and the filament tip catches on it. Use fittings the tube can pass all the way through (PC4-M10). The maintainer called this "one absolutely diabolical issue to debug".
Extruders that take only 2 mm ID tube (Orbiter and others) need a smooth, tapered 3-to-2 mm transition just before the extruder. Bambu Lab couplers aren't suitable. Use the printed PTFE tube coupler v5, with an ECAS04 collet in each end: the 3 mm ID tube goes in its 3 end, and the 2 mm ID tube in its 2 end. Cut the tube ends square, and push each tube in until it bottoms out.
Prepare every tube end. Cut it square, lightly chamfer the inside edge so the tip can't catch at the joint, and push it in until it bottoms out. Don't clamp a tube so hard that it goes oval: that narrows the bore.
Keep the curves gentle: no bend tighter than about 100 mm radius. The last one, into the toolhead, matters most; brittle filament snaps there first. Keep the tube clear of the frame and the enclosure at every Z height. A tube pressed against a top panel at high Z triggers the FPS early.
More than one AMS on one toolhead. The tubes from each AMS join in a printed PTFE splitter before the buffer. The splitter is one more joint: a 3 mm bore all the way, with no step inside. Each AMS has its own path length to the extruder, so set ptfe_length for each one.
The FPS case must not grip the tube (OpenAMS 1). The tube has to slide freely where it enters the case. An over-extruded print, or a hole printed too tight, adds friction right at the sensor. The slide itself needs no lubricant. The tube does benefit from a little EP2 grease where it touches the FPS case and where it comes out at the outlet.
Left: two push fittings; the PC4-M6 at the bottom leaves a step inside around a 3 mm ID tube. Middle: the printed PTFE tube coupler v5. Right: the coupler in section, with each tube seated against its stop and a smooth taper from 3 mm to 2 mm.
The hand test. Disconnect the tube at the toolhead. Take a fresh, undamaged piece of filament and push it by hand through the whole path, from the AMS end to the extruder gears. It should slide with no catch anywhere, and come back just as easily. If you feel a snag, that's where your loads will stop. Repeat with short pieces of tube at each fitting and transition, going in at an angle the way a real filament tip would.
Only the spring supplied with your hardware is supported. No other spring, stiffer or otherwise.
Use the spring that came with your hardware.
Both are stiffer than the spring Bambu Lab fits, to allow for the longer tube of a Klipper printer.
The spring in the FPS kit, if you need to source a replacement:
| Wire diameter | Free length | Inner diameter | Outer diameter | Coils | Material |
|---|---|---|---|---|---|
| 0.6 mm | 30 mm | about 11 mm | 12 mm | 6 | Stainless steel 304 |
ptfe_length. A slide that moves early in the load does no harm unless the load stops there, and if it stops there, the path is the problem.Photo: Bambu Lab Wiki, arrow added.
If you have already ground filament:
Left: filament with a stretch chewed flat after the AMS kept pushing against a jam. Right: inside the AMS hub, the ground-off plastic packed around the drive gear.
Toolhead filament switches before the extruder gears, such as the ball and switch inside some FilamATrix and Stealthburner builds, are not recommended:
A stepper-driven MMU needs a switch there, because a stepper only counts steps and needs something to tell it when to stop (how the AMS knows where the filament is). The AMS doesn't, because the FPS already tells it when the filament reached the gears. A switch there is redundant at best. At worst it triggers the FPS early, every time.
FilamATrix has versions with a switch before the gears, after them, or both. If yours has one before the gears, remove that one.
After the gears, a sensor is fine if you want one. It only confirms that the extruder took the filament; the FPS still decides when the AMS stops. Set fs_extruder_out: True in _oams_macro_variables, and a failed check then pauses the toolchange. Two things to watch:
None of this means your sensor is causing trouble. These are failures support has seen many times, and they are very hard to trace when they happen.
The extruder does steps 4 and 8 of every toolchange: it pulls the cut stub out, then grips the new filament. With weak grip, both fail. With grip set too hard, it can bind.
Test it without the AMS. Load filament by hand and extrude, then retract, about 100 mm each way. Then do it again while holding the filament back with light resistance. If it stops extruding as soon as it meets any resistance, it's an extruder problem, and the AMS can't fix it.
Clockwork 2 / Stealthburner. Set the anti-squish screw properly:
Check that the grub screw on the 50T gear shaft sits on the flat and is tight. If it slips, the motor turns but the drive gears don't.
Not too tight, either. Too much tension squashes the filament oval, and the oval end then drags in the tight passage around the gears.
Keep the prime line moderate. A prime line heavier than the hotend can melt makes the extruder skip, and it does so silently.
Don't make the AMS push while the extruder retracts to work around a weak extruder. That isn't a fix. The AMS moves slowly in reverse, and pushing against it chews up filament on every rewind. A recent case looked exactly like this: the unload reported 250 mm of extra retract and the filament was still in the gears. Adding more length couldn't help, because the extruder wasn't moving the filament at all.
A cutter is required, and tip forming isn't supported (the reason is below). If the filament isn't cut all the way through, nothing after the cut can work, however long the retract.
CUT_FILAMENT by itself. It uses your OAMS_CUT if you defined one, or the cut coordinates in _oams_macro_variables if not. Then pull the filament out of the top of the toolhead by hand. It should come out freely, with a clean, flat cut end.pre_cut_x/_y, cut_x/_y, post_cut_x/_y) before your first toolchange. They are the values most likely to be wrong.CUT_FILAMENT moves to the pre-cut position at pre_cut_speed, pushes the cutting arm into its pin at cut_speed, then backs off. If the push is too fast, the X and Y motors skip, and the print's layers shift right after a toolchange. If that happens, lower cut_speed. The sample's 1000 mm/min is about 17 mm/s; other cutters push through at about 10 mm/s (600 mm/min).Move out of range, for example once skew correction shifts the coordinates. Leave a millimetre or two.retract_length sets where the cut is made. Before the cut, the extruder pulls the filament up by retract_length, so the molten end leaves the melt zone. Pull just enough to clear it: about 20 mm on a Dragon (watch a toolchange). Too much draws soft plastic up into the cold heatbreak, where it can clog; too little wastes purge. The reload pushes the same distance back down, so the stub left in the hotend ends up where it was before the cut.Why tip forming isn't supported. Whatever end the extruder pulls out has to go back up through the gears, that 2.4 mm passage and the PTFE tube. A cutter cuts the filament cold, above the hotend, so the end that goes up was never melted and is still 1.75 mm. Tip forming shapes the end inside the melt zone instead. It comes out with a bulb wider than the filament, a spear and often a string, and its shape changes with the material, the temperature and the cooling moves. A bulb wider than the passage stops right above the gears, and the toolchange fails with the filament apparently stuck in the extruder.
After the cut, the extruder retracts extrusion_unload_length at unload_speed, and then another extrusion_unload_additional_length (250 mm by default) at additional_unload_speed. Only after that does the AMS rewind.
max_extrude_only_distance, which is 50 mm by default, and the toolchange fails with Extrude only move too long. Set it above your extrusion_unload_additional_length in [extruder], for example max_extrude_only_distance: 300.OAMSM_UNLOAD_FROM_TOOLHEAD calls your toolhead_unload_macro, and that macro has to eject the filament past the gears, about 100 mm. A stock 30–40 mm UNLOAD_FILAMENT leaves the tip in the gears. The default since 2026-11-08 is _OAMS_TOOLHEAD_EJECT, which ships with OpenAMS; if your oams.cfg still sets toolhead_unload_macro to your own macro, remove that line.The AMS is not a set of parts you can swap one at a time. The spool, the front rollers, the rear rollers and their bearings were sized together, and each one depends on the others. Change one, and the rest stop working the way they were designed to. We used to recommend some of these changes; after years of running AMS units, we don't anymore.
So for the spools, the answer is a respooler and Bambu Lab reusable spools, not a printed tray, roller or rim.
The AMS is built for ordinary 1.75 mm filament on Bambu Lab spools. Filament it can't handle jams in the path, and it looks just like an AMS fault.
Each of these looked like a fix to someone, and each one hid a printer-side problem until it came back worse:
| Workaround | What it actually does |
|---|---|
| A stiffer buffer spring (any spring other than the one supplied), so the slide stops triggering early | The hub motor grinds the filament at the snag; flat spots, dust in the hub |
Adding an offset to ptfe_length, so the AMS ignores the FPS for longer |
If the count is off by even a millimetre, the AMS doesn't know when to stop. It reaches the extruder at full speed and slams the buffer shut; the maintainer warned this eventually breaks the buffer slide where the two M2 screws hold it |
| Running the AMS forward or backward together with the extruder, to help a weak extruder | Filament chewed on every rewind; the extruder is still weak |
| Rewriting the macros (for example with gco-routines) so the AMS rewinds while the extruder is still retracting | The AMS pulls on filament the extruder still holds, and its slow rewind chews it. The real cause (the grip, the cut or a stiff spring) is still there. The only overlap OpenAMS supports is the load running while the nozzle is cleaned: the AMS never rewinds before the extruder has let go |
| A toolhead switch "to be sure" | One more snag point in front of the gears, and it can't tell you the filament is touching them |
| Retract length raised again and again | Hides a cutter that doesn't cut, or an extruder that doesn't grip |
| A Hydra or other printed tray, so the AMS takes any spool | Replaces the rollers and bearings the AMS was designed around; it works worse than the stock AMS |
| Larger front rollers, so the AMS respools faster | Less torque at the spool: a large or heavy spool stalls |
| Printed rims on cardboard spools | Usually makes the spool larger across: it rubs against the case and cuts into the rubber front rollers |
When the FPS triggers early or the AMS stops, find out where the filament caught, and fix that.
One user's conversation in 2025 covers most of this guide. It ran from early September to mid-October, around 250 messages. Their own words, quoted below, are kept anonymous. The AMS worked correctly the whole time. Every problem was in the setup around it.
| When | What happened | What it really was |
|---|---|---|
| Sep 7 | The FPS board wasn't found; the user had set up CAN without the FPS acting as the bridge. Firmware flashing needed -d 0483:df11 added to dfu-util. |
CAN and bootloader setup |
| Sep 7 | After a calibration, Klipper stopped responding to the AMS and the filament had to be pulled out by hand. | A hung CAN bus; a full power cycle cleared it |
| Sep 11–14 | The FPS kept triggering before the filament reached the extruder. The user was on 2 mm ID tube, later bought 2.5 mm and 3 mm to compare. | Wrong tube ID |
| Sep 14 | Filament "catches on the stainless steel ball sensor [in the hotend], and with a pretty strong resistance." | A toolhead switch in front of the gears |
| Sep 11–14 | Wanted a toolhead switch for confirmation instead; couldn't get its GPIO working; removed it. | Unneeded hardware |
| Sep 14 | "I calibrated the PTFE length and then added 99 to it. Now the FPS only triggers right before the filament reaches the gears." | Compensating instead of correcting. The maintainer: "I hope you understand this is not how it should be…" |
| Sep 13–14 | The FPS triggered early at high Z: the tube pressed against the top panel. Also, the tube was tight in the printed FPS case. | Tube routing and printed-part friction |
| Sep 23 | Shavings of filament found in the tube. | A sharp edge on a redesigned motor plate, and the follower test below |
| Sep 23 | Testing follower commands by hand with the direction reversed: "the gears would start to shred the filament at the toolhead." | Learning what the follower does by trial on the machine |
| Oct 11 | "I just now need a way to get orcaslicer to send a T0/T1/T2/T3 command dependent on which filament is in the AMS." | How a multi-material slicer works (section 2) |
| Oct 11–12 | The printer loaded one filament at print start, then changed to another. | The start macro's initial_tool didn't match the first color |
| Oct 12 | Nozzle jam after a failed prime line; possibly metal debris in a tube; the hotend was replaced. | Hotend |
Sections 2 and 3 of this guide answer nearly every row. None of the rows needed a change to OpenAMS.
The most common symptoms, and the check that settled most of them.
| You see | Usually | First check | More |
|---|---|---|---|
Klipper won't start once oams.cfg is included |
A <your_unique_..._UUID> placeholder still in the file; a missing or duplicated section; another MMU system's config |
python3 ~/openams/tools/agent/config_audit.py --config-dir ~/printer_data/config |
6.1 |
OpenAMS 1: a board isn't found: Timeout on connect, Unable to connect, no UUID |
CAN wiring or termination, a wrong UUID, or a bus that needs a full power-off | Stop Klipper, power off fully, then canbus_query.py. Check errors with ip -s link show can0 |
6.2 |
| A print paused in the middle of a toolchange | Any failed step: the cut, the retract, the feed (the load and the reload) | Read the message, fix what it names, then RESUME: it retries from where it stopped |
2 |
A load stops before the toolhead, the FPS slide compresses early, or loading speed too low |
Friction or a step in the filament path; wrong tube ID; a switch in front of the gears | The hand test in section 3, and 3 mm ID tube | 6.3 |
| OpenAMS 1: the FPS reading is backwards, stuck, or doesn't change | fps_is_reversed; the slide's magnet not engaged; an assembly fault |
Push the slide by hand: about 0 relaxed, about 1 pushed home | 6.3 |
An unload pauses with unloading speed too low, or the filament stays in the extruder |
The cut didn't go through; the extruder still holds the filament | Unhook the tube at the toolhead and pull by hand; then CUT_FILAMENT alone |
6.6 |
| Unloads fine by hand, but in a toolchange the filament stays in the gears once the AMS starts to rewind | A buffer spring stiffer than the one supplied, fighting the retract; macros changed so the AMS rewinds while the extruder is still retracting (for example with gco-routines); or a cut end that isn't clean, or a formed tip, jammed in the passage above the gears | Put back the supplied spring and the stock oams_macros.cfg (the config audit reports edited macros as E_MACRO_CUSTOMIZED). Then CUT_FILAMENT alone, and check the end |
6.6 |
Extrude only move too long during a toolchange |
max_extrude_only_distance is below the 250 mm extra retract |
Raise it in [extruder] |
6.6 |
| Flat ("bald") spots on the filament; dust; feeders slipping | The AMS kept pushing against a jam; a spring that's too stiff | Cut back the damaged filament, blow out the hub, then find the jam | 6.5 |
A bay isn't detected; a feeder runs on and on; Group T1 has no bays assigned |
Dust in the hub; bay sensor thresholds; the group config | OAMSM_SELFTEST, then blow out the hub |
6.7 |
| The printer loads one color at the start, then switches to another | The start macro's tool doesn't match the first color | TOOL=[initial_tool] into PRINT_START |
6.8 |
| A runout pauses instead of switching spools | ptfe_length is still 0; no spare bay in the group |
OAMS_CALIBRATE_PTFE_LENGTH OAMS=1 SPOOL=<bay> (OpenAMS 1, Cortex Bridge firmware 8 or later); older bridge firmware: measure the path and set it |
6.11 |
| The AMS keeps pushing after a cancel or an emergency stop | The follower is still on | OAMSM_FOLLOWER ENABLE=0 DIRECTION=1, then OAMSM_CLEAR_ERRORS |
6.11 |
| OpenAMS 1: a board went dead, a fuse blew, or there was a burning smell | Overvoltage or a wiring fault | Power off. Check the fuse for continuity with the power disconnected. Ask support | 6.9 |
| The Mainsail panel or the display shows no units | The printer still runs klipper_openams |
Move to OpenAMS | 6.12 |
| A Bambu spool is listed twice in Spoolman | Made once per tag by an older version or by another tool | curl http://<printer>:7125/server/openams_spoolman/duplicates, then merge them: Spool tags and Spoolman |
6.12 |
Cortex Bridge: no AMS, Unable to open serial port '/dev/oams/...', or an LED off |
Power, cables, or Klipper started before the AMS was up | python3 ~/openams/tools/cortex-bridge.py status, and do what its last line says |
6.13 |
Cortex Bridge: a load stops just short of the toolhead, and the message says the reading stayed below arrival_threshold |
Friction in the path; or a threshold above what your buffer reaches | The hand test first; then lower arrival_threshold |
6.13 |
Cortex Bridge: a load stops well short of the toolhead with the AMS stopped feeding before the toolhead buffer reached arrival_threshold and fault motion_timeout |
ptfe_length is shorter than the path; or a snag |
Look where the tip stopped. Running freely: set ptfe_length to the old length + 200 mm + the gap at the gears. Stuck at a joint: fix the path. Then Clear errors (OAMSM_CLEAR_ERRORS) |
6.13 |
Cortex Bridge: a load slows to a creep at the toolhead and stops with the toolhead buffer never reached arrival_threshold and fault motion_timeout, although the filament reached the gears and the buffer is compressed |
OpenAMS before 2026-11-08 (evening): the first load after a Reset (OAMSM_CLEAR_ERRORS, or the Reset RESUME runs) could reuse an operation number, so its arrival was never confirmed |
Update OpenAMS. Until then, an unload before the load avoids it. Then Clear errors (OAMSM_CLEAR_ERRORS) |
6.13 |
| The toolhead drives into a corner and hits the frame when a toolchange fails, and later cuts miss the cutter | OpenAMS before 2026-11-08 (evening): a toolchange that had to home first moved back to the position from before homing (0, 0, 0 after a restart) | Update OpenAMS, then home again (G28): the crash cost the toolhead its position |
2 |
OpenAMS could not finish the toolchange ...: Recovery macros cannot start managed routines |
gco-routines older than 2026-11-08 (evening): RESUME cannot run the toolchange again | Update gco-routines (git -C ~/gco-routines pull), restart Klipper, then press RESUME |
2 |
OpenAMS cannot retry the failed toolchange: the printer lost its position |
The motors went off while the print waited, so RESUME would have to home with the part on the bed | Nothing was moved; cancel the print | 2 |
OpenAMS will not run the toolchange to <group> while the print is paused: the printer lost its position |
A Load, Unload or Retry while the paused print's motors were off: it would have homed with the part on the bed | Nothing was moved; cancel the print first | 2 |
Cortex Bridge: an unload stops with Spool unloading failed (the filament did not move back: ...) |
Bridge firmware 14 or later: after the cut the AMS pulled, but its odometer stood still, so the bridge stopped it within seconds. Almost always the cut did not sever the filament, or the cut end is caught in the toolhead | Check the cutter and free the end, then Retry: it cuts again before the AMS pulls. Bridge firmware 12 and older pulled for a minute first and said no filament progress (jam, dead motor, or missing sensor) |
the cutter |
Cortex Bridge: a load stops with the AMS reported a jam (error 0x17) |
The AMS's own feeder stalled: a spool that turns hard (a cardboard spool, a tangle) or filament caught near the AMS | Free the spool or the filament, then Retry. Wind filament from a cardboard spool onto a Bambu Lab reusable spool (why) | 6.5 |
Cortex Bridge: an unload stops with the AMS reported a feeder motor fault (error 0x12) |
A feeder motor of the AMS could not turn. Seen on an AMS 2 Pro pulling the filament back while its end was still held at the toolhead; filament wound tight on the spool can do the same | Free the filament at the toolhead or the spool, then Retry | the cutter |
<unit>: cleared the motion_timeout fault left by an earlier failure; the unload that just finished worked |
An unload that works shows the AMS moves again, so OpenAMS clears the motion fault the AMS kept from the failure before it (it would refuse the next load). A dryer or system fault is never cleared this way | Nothing. If it says could not clear, press Clear errors (OAMSM_CLEAR_ERRORS) |
2 |
| Mainsail still says to FIRMWARE_RESTART after a bridge or AMS firmware update | Klipper was restarted while an AMS was still coming back | Press FIRMWARE RESTART in Mainsail. It is expected now and then, and harmless | 6.13 |
<unit> is already drying (timed_dry, <n> min left); to change the temperature, the time or Rotate, stop it first (OAMS_DRYER_STOP) |
A dry already runs on that AMS, for example when Rotate is switched on during a print | Nothing, if it should go on. To change it: OAMS_DRYER_STOP OAMS=<n>, then start again |
Drying |
<unit> cannot turn its spools during a print; start the dryer without Rotate (ROTATE=0) |
Spools never turn while a print runs or is paused | Start the dry without Rotate. An AMS HT on firmware 04.x or later dries while you print | Drying |
<unit> is drying with its spools turning, so it cannot feed; stop the dryer (OAMS_DRYER_STOP), or start it again without Rotate, before loading <group> |
A turning spool is free, with its filament back out of the AMS's first stage | Stop the dryer, or restart it without Rotate, then load | Drying |
<unit> is drying and does not feed; stop the dryer (OAMS_DRYER_STOP) before loading <group> |
This AMS does not feed while it dries (an AMS 2 Pro, or an AMS HT on firmware 03.x) | Stop the dryer, or wait for it to finish, then load | Drying |
A fault says Clear errors did not clear it: power the AMS off and on, or Clear errors answers ... still latched after the clear |
The AMS keeps its own error, or (Cortex Bridge firmware 20 and older) it still reports moving and refuses the clear | Power the AMS off and on (an AMS HT or AMS 2 Pro also needs its power adapter unplugged), then press Clear errors again. Cortex Bridge firmware 21 stops a unit that still reports moving before it clears | 2 |
A failed Load or Unload from the panel stays as not finished after Clear errors |
Clear errors keeps it so Retry can finish it from where it stopped | Retry finishes it, Unload backs it out, Abandon (OAMSM_ABANDON) forgets it and leaves the filament where it stopped |
2 |
OpenAMS: the print needs <group> loaded on lane <lane> |
RESUME found the toolhead empty, or holding another group than the print was using | Load that group (T<n>, or the panel), then press RESUME |
2 |
| After an Unload or a Load during the pause, RESUME printed on with an empty toolhead or the wrong filament; or RESUME homed the printer with the part on the bed | OpenAMS before 2026-11-09 | Update OpenAMS | 2 |
The most common problems come first.
Applies to: both.
How you'll recognize it. Klipper stops at startup once [include oams.cfg] is in printer.cfg. OAMS_… commands answer Unknown command. A macro fails with a jinja2 … UndefinedError. A group that is clearly loaded reports that it has no bays.
Usual causes, most frequent first:
oams.cfg (OpenAMS 1). A fresh install ships with <your_unique_..._UUID> placeholders, and the tag key placeholder. An error on the first start is expected. On a Cortex Bridge printer, the installer writes each AMS's sections for you. Replace them (configure).Unknown command, Section ... is not a valid config section). Restart the Klipper service, or run ./install.sh again.[filament_group T1] twice, or one bay in two groups. Klipper now stops and names the duplicate. Every bay in a group must share one FPS lane.[pause_resume] and [exclude_object] in printer.cfg, and your own CLEAN_NOZZLE macro.pin PA2 used multiple times. Remove the other system's config for that toolhead.oams_macros.cfg is a link to the checkout, and every update replaces it. Put changes in your own file through OAMS_CUT, CLEAN_NOZZLE and the _OAMS_HOOK_* macros (customizing the toolchange). The config audit reports E_MACRO_CUSTOMIZED when it finds one.klipper_openams sample config or instructions. Use the oams_sample.cfg from your ~/openams checkout.Fix. Run the config audit and work through its findings top down:
python3 ~/openams/tools/agent/config_audit.py --config-dir ~/printer_data/config
Then run the bring-up ladder, and fix the lowest failing level first:
python3 ~/openams/tools/agent/bringup_check.py --selftest
Good to know.
use_kalico: option is accepted and ignored.oams.cfg (SAVE_CONFIG can't edit an included file). If your sections live in another file, set openams_config_path: under [oams_manager].Collect: the audit output, klippy.log, oams.cfg, and the [include ...] lines of printer.cfg.
Applies to: OpenAMS 1. A Cortex Bridge uses USB, not CAN; see 6.13.
How you'll recognize it. mcu 'oams_mcu1': Unable to connect or Timeout on connect. Only one of the two boards answers canbus_query.py. Boards that come and go after a restart. Another CAN device stops being found once the AMS is added. Timer too close, or Lost communication with MCU, during a toolchange.
Usual causes, most frequent first:
The wrong topology for your printer.
can1).Termination. A CAN bus needs exactly two 120 Ω terminations, one at each physical end. Remove the FPS's termination jumper when it sits in the middle of the bus. Wrong termination is a common reason why another device, such as a probe, drops off once the AMS is added.
Boards that need a real power-off. A board that hung, or one that was just flashed, often doesn't come back after FIRMWARE_RESTART or a host reboot. Power the whole printer off and on.
Querying while Klipper runs. canbus_query.py lists only boards that Klipper hasn't claimed yet. To see every UUID:
sudo systemctl stop klipper).~/klippy-env/bin/python ~/klipper/scripts/canbus_query.py can0
Cables and power. Use twisted-pair cable, of a matching gauge, and shielded on long runs. Also check the host's own supply: a Raspberry Pi that reports undervoltage drops USB devices, the USB-to-CAN bridge included. Use a 5 V 3 A+ supply, or a Pi 5.
Firmware built for the wrong CAN pins, so two boards report the same UUID or the mainboard never appears. Rebuild with the settings from the firmware guide for that board.
An overloaded host. Timer too close during a toolchange usually means the host fell behind. Common causes are cameras, extra services, a slow SD card, or a Pi that's throttling (vcgencmd get_throttled). Turn the extras off while you test, and check the bus's error counts below.
Fix. Check the bus first:
ip -s link show can0
Look at the state, the bitrate, and the TX/RX error counts. Then check the UUIDs, then power and cables. If the bus still drops boards, or a bridge keeps rebroadcasting, OpenAMS ships an optional series of Klipper CAN fixes (./install.sh --with-klipper-patches). See the CAN patches guide.
Collect: ip -s link show can0, the canbus_query.py output, a sketch of the bus (what connects to what, and where each termination is), and klippy.log.
Applies to: both. The FPS settings are OpenAMS 1; a Cortex Bridge has its own note at the end.
How you'll recognize it.
loading speed too low, with the bay LED red.OAMS_CALIBRATE_PTFE_LENGTH gives a different length every time, or one that's far too short.Usual causes, most frequent first:
fps_is_reversed: in [oams oams1]. That's the value the AMS stops on. A PTFE calibration that ends at a length of 150 mm, or loads that never stop, are typical signs. Separately, flip reversed: in [fps] if the UIs draw the pressure bar backwards.Fix.
OAMSM_SELFTEST reports it, and so does level L5 of the bring-up ladder. A relaxed slide should read about 0, and one pushed home about 1.OAMS_CALIBRATE_PTFE_LENGTH OAMS=1 SPOOL=0
Don't add an offset to ptfe_length, and don't fit a stiffer spring. Both hide the snag instead of removing it (why).
With a Cortex Bridge, the buffer is Bambu Lab's, read through the AMS, and the host decides when the filament has arrived. If a load stops just short of the toolhead with a message that the reading stayed below arrival_threshold:
arrival_threshold: in [fps] to just under the peak the message names (details).If a load stops well short of the toolhead instead, with the fault motion_timeout, look at where the tip stopped. If the filament runs freely and simply stopped, ptfe_length is too short: the bridge stops a full-speed load about 200 mm past it. The path is about the old length, plus 200 mm, plus the gap left at the gears. Don't set the length longer than the path to be safe, either: the runout reload starts from it, so a long one reloads late.
A buffer whose slide bottoms out often reads only about 0.75, never 1.0.
Collect: the FPS values with the slide relaxed and pushed home, photos of the path, the tube ID, and the calibration output.
Applies to: OpenAMS 1. Nothing on a Cortex Bridge printer is flashed by hand; the bridge's own firmware comes with OpenAMS updates (update the Cortex Bridge firmware).
How you'll recognize it.
dfu-util finds no device, or ends with Error during download get_status.Device's firmware is corrupt.FlashError: Error sending command [CONNECT].Usual causes, most frequent first:
lsusb shows 0483:df11.dfu-util with sudo.-d 0483:df11.:mass-erase:force on the flash address, then a clean flash.make clean before make, and check make menuconfig against the guide, after any change of target.mixed OAMS firmware protocol versions otherwise, and the RFID readers need 2.0.25 or newer.Good to know.
Invalid DFU suffix signature is a warning. With the :leave option, an error after the download has finished is usually harmless too. Check that the board shows up afterwards before you try again.python3 ~/openams/scripts/flash_bootloader.py. It refuses boards flashed with the standalone image.Collect: the exact command, its full output, lsusb, and which board and image you flashed.
Applies to: both.
How you'll recognize it.
Usual causes, most frequent first:
Every cause in section 3: tube ID, fittings, transitions, curves, the FPS case.
The AMS pushing against a jam. Each time it does, it grinds a flat spot into the filament. Next time, the feeder can't grip that stretch, so the load fails again, in the same place.
Sharp edges in printed parts. A motor plate, an insert, or a cutter body that shaves the filament as it passes.
Filament tips that are bent, flattened or stringy. Cut new tips square or at 45°.
Damp or brittle filament that snaps in the tubes or the hub. See filament and spools.
Worn parts: tubes, couplers and feeder funnels wear out, and then the filament stops in the same place every time. See keeping it running.
Fix.
Collect: photos of the damaged filament and of the path, and the tube ID.
Applies to: both.
How you'll recognize it.
unloading speed too low.Extrude only move too long.Usual causes, most frequent first:
max_extrude_only_distance is below the 250 mm extra retract.oams_macros.cfg.Fix. Work through the cutter, the extruder and the unload in section 3, in that order. Each has a test that doesn't involve the AMS.
Good to know.
OAMSM_CLEAR_ERRORS, and load the next spool.Collect: whether the filament came out freely by hand after the cut, your toolhead, extruder and cutter, and your _oams_macro_variables.
Applies to: both, except the hub sensor calibration, which is OpenAMS 1 only.
How you'll recognize it.
OAMS_CALIBRATE_HUB_HES does nothing but make gear noise.Group T1 has no bays assigned, or No spool is loaded, when one clearly is.Usual causes, most frequent first:
Dust and ground filament in the hub. This is the most common cause, and it's usually left over from earlier grinding. Blow the hub out with compressed air, and push the filament in until it stops.
Bay sensor thresholds. The shipped f1s_hes_on and hub_hes_on values work on most units. If one bay reads as always empty or always full:
OAMS_CALIBRATE_HUB_HES OAMS=1 SPOOL=<bay> for it (OpenAMS mainboard only).oams.cfg if needed.Worn or loose AMS parts. The AMS is a used machine in many conversions:
After opening the hub, check that its four magnets face the right way, or the bays read wrong.
Swap the feeder cables between bays to find out whether a fault follows the part or stays with the port.
The group config. The bay isn't in the group you called, or a group name appears twice.
Spools that slip, rub or tip over. Cardboard spools slip on the rollers, a spool with printed rims rubs against the case and wears the front rollers, and a nearly empty spool in an AMS 2 Pro can tip over. Use Bambu Lab reusable spools in a stock AMS (The AMS is one system).
The driven roller isn't seated. Each bay has one black, driven support shaft under the spool. If it isn't pushed fully into the AMS frame, the feeder's gear turns and hums, but the spool doesn't, and the rewind fails. Push it home.
Collect: the OAMSM_SELFTEST output with the bay empty and with it loaded, klippy.log, and your [filament_group] sections.
Applies to: both.
How you'll recognize it.
Usual causes, most frequent first:
TOOL=[initial_tool] to PRINT_START, and call T{TOOL} there.T[next_extruder]; the macros stay in Klipper.extrusion_reload_length on your toolhead until the new filament just reaches the nozzle tip without oozing (how).Collect: the slicer's machine start and change-filament G-code, your PRINT_START, and the first 100 lines of a sliced file.
Applies to: OpenAMS 1. For the Cortex Bridge's power and LEDs, see 6.13.
How you'll recognize it. A board that disappears with its LED off. A burning smell. Random disconnects. A fuse that measures open.
Usual causes, most frequent first:
Power off before you plug. Switch everything off before you plug or unplug the AMS, FPS or CAN cables. If the FPS and the printer run from different power supplies, connect the two supplies' V− together.
To keep printing while you wait for a part: a dead board stops Klipper from starting, so comment out [include oams.cfg] in printer.cfg until it's replaced. With working boards you don't need to: just print without the AMS.
Collect: photos of both sides of the board and the wiring, the continuity results, and what happened just before the failure.
Applies to: OpenAMS 1. For the Cortex Bridge, see Print and mount the case and the buffer case.
STLs and CAD: the filament-buffer repository. CAD/FPS v4.step holds the whole assembly. If an STL is missing, export it from the STEP, and tell the maintainer.
The slide is Bambu Lab's, reused inside the FPS case. Fit the FPS kit's spring, not Bambu's.
The tube in the slide should only touch the end of the slide, not pull through the ECAS lock. Trim it if the slide doesn't spring back.
Print the FPS case in ABS or ASA. A PLA case cracked and jammed the slide. Use machine screws (M3x6 in the M3 heat-set insert).
Grease (EP2) goes on the tube where it touches the case and where it comes out at the outlet. Bambu Lab's slide needs no lubricant.
RFID readers are optional. OpenAMS works without them. With them, a spool's tag is matched to its bay and to its Spoolman spool, both tags of a Bambu spool counting as one: Spool tags and Spoolman.
A cutter is required (see 6.6).
Applies to: both.
How you'll recognize it. A runout that pauses instead of switching. The AMS pushing filament after a cancel, an emergency stop or a power cycle. Filament shredded at the toolhead during manual tests.
Usual causes and fixes:
ptfe_length is still 0: calibrate the AMS once, on any bay with filament, since every bay shares the AMS's path (OpenAMS 1), or measure and set it (Cortex Bridge). Otherwise there's no ready spare in the group, or auto_reload_on_runout is off. The pause message says which.OAMSM_FOLLOWER ENABLE=0 DIRECTION=1, then OAMSM_CLEAR_ERRORS. A failed toolchange now turns the follower off by itself. A display's Stop button stops the whole sequence.DIRECTION=1 pushes toward the toolhead, and DIRECTION=0 pulls back. With ENABLE=0 it stops, whatever the direction. Pulling back while the extruder pulls forward shreds filament.
OAMSM_FOLLOWER, which acts on the loaded lane.OAMS_FOLLOWER needs OAMS=<index>.Applies to: both.
./install.sh --mainsail-panel. Reload the page with Ctrl+Shift+R, and scroll down: the panel may be at the end of the first column.klipper_openams. Move to OpenAMS.[display], ./install.sh adds an OpenAMS entry to the display's main menu: load, unload, retry, tags, calibration and the dryer from the knob. The printer's LCD menu.More is in the guide's Mainsail panel section.
Applies to: 0AMS.
Start here, every time:
python3 ~/openams/tools/cortex-bridge.py status
It checks the USB link, the relay and each AMS, and its last line names the first thing to fix.
| You see | Usually | Do |
|---|---|---|
| No LEDs, or one off | White off: no USB power. Red off: no 24 V at the buffer connector | Check the USB cable (it must be a data cable, in a port on the computer itself), and the 24 V wires, their polarity and the 5 A fuse. The board guide explains each LED |
The bridge is not on USB |
A charge-only cable, a bad port, or a USB hub | Another cable and port |
No AMS answers |
The buffer or AMS cable, or AMS power | Check the red LED, the 4-pin buffer cable and the 6-pin AMS cable; power the AMS off and on |
Klipper: Unable to open serial port '/dev/oams/...' |
Klipper started before the AMS was up | Wait until status shows the AMS online, then FIRMWARE RESTART |
Klipper: Can not update MCU '...' config as it is shutdown |
Klipper was stopped for a while. The bridge stops an AMS whenever Klipper goes quiet, so nothing runs unattended | FIRMWARE RESTART. Nothing is wrong |
<ams> Spool N has no PTFE length |
ptfe_length is 0 for that bay |
Firmware 8 or later: OAMS_CALIBRATE_PTFE_LENGTH OAMS=<n> SPOOL=<bay>, as the message says. Older bridge firmware: measure the path, convert it with cortex-bridge.py ptfe <mm>, set ptfe_length and FIRMWARE RESTART |
| Loads stall, or the buffer reports arrival before the filament reaches the toolhead | Friction in the filament path | Section 3: 3 mm ID tube up to the coupler, gentle bends, the stronger spring fitted |
| An unload ends in a unit fault | The filament tip stayed in the extruder gears | toolhead_unload_macro at its default, _OAMS_TOOLHEAD_EJECT, and the unload checks |
To send support everything in one file:
python3 ~/openams/tools/cortex-bridge.py support
The full table is in the Cortex Bridge setup guide.
The AMS's own LEDs. With the Cortex Bridge, the AMS keeps its stock Bambu Lab electronics, so its bay LEDs blink the same codes as on a Bambu printer. Bambu Lab's AMS LED status page explains them. They don't apply to OpenAMS 1: its mainboard replaces Bambu Lab's, and it sends its errors to the printer, so read them in the Klipper console.
Applies to: both.
Parts of the filament path wear with use. A worn part causes the same symptoms as a bad setup: a load that stops in the same place every time, or a buffer that triggers early.
Every few months, and more often with filled filaments:
Collect these first. Most threads in the channels spent their first day asking for them.
python3 ~/openams/tools/agent/bringup_check.py --selftest
python3 ~/openams/tools/agent/config_audit.py --config-dir ~/printer_data/config
(With a Cortex Bridge: python3 ~/openams/tools/cortex-bridge.py support writes a report to attach.)klippy.log from the failing attempt (~/printer_data/logs/klippy.log), not a screenshot of the console. OpenAMS logs the FPS value, the bay sensors and the encoder there.oams.cfg, and say whether you changed oams_macros.cfg. You shouldn't need to: customizations belong in your own file, through OAMS_CUT and the hook macros.If one of the hand tests fails, fix that first. It's almost always the answer, and you'll have found it faster than any reply could.